Cross Cancer Institute Uses Simulation to Optimize MRI Treatments
Gino Fallone and colleagues
Cross Cancer Institute
Edmonton, AB, Canada
Radiation therapy targeting in cancer treatment involves many uncertainties, including the movement of targeted sites due to breathing and the like. Magnetic resonance imaging (MRI) can accurately identify the location of a tumor in soft tissue, but unfortunately its magnetic field can interfere with radiation treatment delivered by a linear particle accelerator (Linac). A team of researchers at the Cross Cancer Institute (CCI) in Canada set out to create a simulation that would make it possible for MRI to be used simultaneously with Linac radiation treatment so that patients can receive the care they need in a much more efficient fashion. On the other hand, the electromagnetic field from MRI can influence the path of electrons produced by Linac.
A magnetostatic simulation was needed to establish a means of shielding the Linac radiation treatment from the MRI’s magnetic fields. The shield that the CCI designed is more than three times lighter than the original, and it dramatically reduces the MRI’s field inhomogeneity by more than three times. It meant they could combine MRI and Linac in order to form an ideal treatment system that could pinpoint any tumor at all times during treatment.
COMSOL Multiphysics was also used to design a 30-cm-long Linac system generating a 10 MeV electron beam--this means that significantly less room is needed to house the Linac-MR treatment system. The optimal combination of MRI and Linac, and the room in which the new installation would be housed was evaluated with COMSOL Multiphysics. Simulation played a vital role in the progression towards clinical use of such a combination. The simulations verified that designing the Linac MR scanner to move together as one whole system provided the best results.
Suggested Stories
Gaining Insight into Piezoelectric Materials for Acoustic Streaming
Many sensors, such as flow sensors and those used in medical diagnostics, rely on microfluidic devices. However, ...
3D Modeling of Armor Losses in High-Voltage Cables
NKT HV Cables used numerical modeling to investigate electromagnetic fields and calculate armor losses in 3D cable ...
Get a Quick Look at How Plastometrex Uses COMSOL Compiler™
Step into the world of the startup company Plastometrex to see how they developed an efficient method for measuring ...
Picking the Pattern for a Stealth Antenna
Stealth airplanes and ships avoid radar detection by optimizing the shape of surfaces to reflect away from the radar ...