G. Potter
SUNY Albany, NY, USA
Many sensors, such as flow sensors and those used in medical diagnostics, rely on microfluidic devices. However, mixing and pumping fluids becomes challenging because of the small size of these devices. As an alternative to traditional actuation methods, surface acoustic waves (SAWs) can be used to create fluid streaming. Through a collaboration between SUNY Albany and SEMATECH, researchers have modeled and simulated a configuration of interdigitated transducers (IDTs), along with the piezoelectric substrate configuration and harmonic vibrations that generate SAWs. Using COMSOL Multiphysics, they studied the factors that affect the optimization of the device geometry, such as the acoustic streaming response and resonant frequency. Using their simulation results, they have confirmed that SAWs with greater vertical displacements have higher streaming velocities, and have correlated their results to experimental measurements.
Suggested Stories
A Smooth Optical Surface in Minutes
Zeeko Ltd is a technology company that manufactures corrective polishing machines for optics and other surfaces. They ...
Dielectric Stress Simulation Advances Design of ABB Smart Grid-Ready Tap Changers
Consumers of power rely on fairly stable voltages. Transformers contain tap changers which vary the ratio of secondary ...
Communicating from Space: The Front End of Multiscale Modeling
As satellites and astronauts travel further out in space, the more communication challenges they are faced with. This ...
Fine Tuning for Water Purification
Amsterdam Water Supply (AWS) of the Netherlands produces some of the cleanest drinking water in the world using an ...
